본문 바로가기

AccE GC85A

ACCELERATING INTELLIGENCE AccE GC85A vision +
Fully Automated System

AccE GC85A enables fully automated operation with the utilization of the THU, motorized wall stand and patient table.

AccE Glass-Free Detector

AccE Glass-Free Detector is designed to relieve users’ fatigue with approximately 2 kg (4.5 lbs) light weight through glass-free technology, but maintains high image quality with high DQE.

Accelerating Intelligence

By providing advanced low dose imaging and a streamlined workflow,
our AccE GC85A allows for a more one-on-one patient experience.
Resulting in improved patient care.

S-Align™ S-Align™ S-Align™

* GC85A Vision+ is a sub-configuration of GC85A with Vision Assist.

upgradeVision Assist

Samsung’s latest camera solution is focusing on innovative ways to
increase the efficiency of DR Imaging. Vision Assist allows for
continuous patient monitoring, improved workflow and patient safety.

For Positioning

Virtual Overlay

Display a virtual drawing of the receptor boundary and AEC chamber onto the patient

Virtual Overlay

Virtual Collimation

Allow to adjust collimated area on the workstation

Virtual Collimation

Motion Alarm

Alarm when the patient moves or falls after positioning

Motion Alarm

Patient Size Guide*

Recommend patient size and optimal parameters based on body thickness

Patient Size Guide

Intelligent Collimation

Provide optimal collimated area with AI technology

Intelligent Collimation

Vision Stitching

No more cumbersome setup

Vision Stitching

Camera Zoom

A variety of camera view controls for usability

Camera Zoom

Vision Capture

Offer a companion patient picture of an X-ray image

Vision Capture

* On-screen contents simulated for illustrative purpose. Actual UI may vary depending on software version, region and other factors.

Diagnostic Confidence

Low Dose in S-Vue

S-Vue™ not only provides excellence in image quality, but also secures better patient safety in radiography examinations.

This can help change the patient’s perspectives for x-ray radiation and improve patient satisfaction.

The dose level can be reduced up to 45% dose reduction for pediatric abdomen, 15.5% for pediatric chest, and 27% for pediatric skull exams with advanced denosing algorithm.​

  • Bone Suppression Bone Suppression
  • Bone Suppression Bone Suppression
  • Bone Suppression Bone Suppression
  • * Note : The claim concerning Samsung DR is based on limited phantom and clinical study results. Only routine PA chest radiography and abdominal radiography for average adults and pediatric abdominal, chest, skull radiography were studied, excluding pediatric patients under 1 month old.(FDA cleared - K172229, K182183)In practice, the values of dose reduction may vary accordingly. These clinical images calculates the dose reduction rate from its own standard dose at the clinical site, unlike our FDA claim which compares dose between new IPE and old IPE. The clinical site is responsible for determining whether the particular radiographic imaging needs are not impacted by such x-ray dose reduction.
  • ** Case 1 image was taken with GM85. / Case 2,3 images were taken with GC85A.
  • *** These are clinical dose reduction cases and rates may vary by the exposure condition of hospitals.
S-Enhance*

Without an additional exposure to the patient, S-Enhance creates a companion image to support your diagnosis. S-Enhance improves the clarity of foreign bodies (e.g., tube, line, and/or needle) within images of the Chest, Abdomen, and L-Spine.

* Optional feature requiring additional purchase

SimGrid*

Without the use of a physical grid, SimGrid™ improves image contrast by reducing scatter radiation effects, resulting in superior image quality.

* Optional feature requiring additional purchase

Bone Suppression*

Bone Suppression aids in the visualization of nodules by suppressing the appearance of bones within the chest image and improving the clarity of soft tissue. A companion image can easily be created with one click on the screen. This feature does not require additional exposures to the patient.

* Optional feature requiring additional purchase

CXR Assist

Samsung’s new AI-powered CAD solution, CXR Assist, helps you diagnose 10 of the most common abnormal findings in Chest X-rays and support Tuberculosis screening.
The AI-driven insight will assist you in providing comprehensive patient care and efficiency of radiology workflow.

* Optional feature requiring additional purchase
* CXR Assist CADe is not for sale in the US.

Streamline without Compromise

Fully Automated System

AccE GC85A enables fully automated operation with the utilization of the THU, motorized wall stand and patient table.

S-Align™ S-Align™ S-Align™
S-Align*

S-Align™ displays the detector’s angle to the THU for precise alignment and enhances the quality of imaging. With S-Align™ Info. to DICOM* feature, the tube/detector angle information is inserted into the DICOM personal tag and can be added as an annotation.

* Optional feature requiring additional purchase
* DICOM Tag : (0033, 1034)
* The image was taken with GM85.
* This feature is only for S4335-AW, S4343-AW detector.

Soft Handling

With a small amount of physical pressure, The Tube Head Unit (THU) can be moved manually by the operator. This feature results in decreased fatigue for the end user.

Expand Premium Experience

S-Share*

S-Share can dramatically increase efficiency through the use of AccE Detector with various existing compatible equipment. It enables accelerating connection for better synergy with premium digital radiography systems.

* Optional feature requiring additional purchase

QAP*

QAP assures improved imaging performance in a precise and cost-effective way.
It enables comprehensive system management by automatic periodic test measuring multiple parameters such as source performance,
AEC accuracy, geometry accuracy, and detector performance with image quality.

Shared Bucky™ Shared Bucky™
QAP Test Setup
Shared Bucky™ Shared Bucky™
QAP Test Result

* Optional feature requiring additional purchase

Shared Bucky

Shared Bucky™ is designed for sharingtwo sizes of
detectors in one bucky tray in the table.

Shared Bucky™ Shared Bucky™ Shared Bucky™

Secure Your Care

Samsung Healthcare Cybersecurity

  • Intrusion Prevention

    Tools for protecting against cyber threats from external attacks

  • Access Control

    Strengthened surveillance for tracking the access of patient information

  • Data Protection

    Encryption functions for safeguarding data whether at-rest or in-transit

LEARN MORE

The described product information, including features and options, is CE marked. Regulatory approval/clearance status may vary by country.